{"id":394,"date":"2020-12-06T02:19:08","date_gmt":"2020-12-06T02:19:08","guid":{"rendered":"https:\/\/fcsinterns1708.firstcomdemo.com\/val\/mitech\/?post_type=case_studies&#038;p=394"},"modified":"2021-01-21T10:30:20","modified_gmt":"2021-01-21T10:30:20","slug":"heating-element-assembly-machine","status":"publish","type":"case_studies","link":"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/","title":{"rendered":"Heating Element Assembly Machine"},"content":{"rendered":"<p><strong>Product<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Assembly of Heating Element.<\/span><\/p>\n<p><strong>Scope<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> New Machine Design &amp; Development.<\/span><\/p>\n<p><strong>Main Features:<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Machine comprises of a rotary table with loading of parts via auto tray loader, vibratory bowl and unloading of finished part via auto tray loader.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">2 units of 6 axis articulated robots are employed for parts transfer.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">The processes involved the insertion of O-ring seal onto a ceramic component which are then further inserted into frame.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Final quality check by a customized vision system.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Include Data logging for traceability.<\/span><\/li>\n<\/ul>\n","protected":false},"featured_media":1807,"template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"case_study_categories":[25],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Heating Element Assembly Machine - \u5236\u9020\u96c6\u6210\u6280\u672f<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data1\" content=\"0 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/#website\",\"url\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/\",\"name\":\"\\u5236\\u9020\\u96c6\\u6210\\u6280\\u672f\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/wp-content\/uploads\/2020\/12\/main-20180314_103901-2-scaled.jpg\",\"width\":2560,\"height\":1920},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/#webpage\",\"url\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/\",\"name\":\"Heating Element Assembly Machine - \\u5236\\u9020\\u96c6\\u6210\\u6280\\u672f\",\"isPartOf\":{\"@id\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/#primaryimage\"},\"datePublished\":\"2020-12-06T02:19:08+00:00\",\"dateModified\":\"2021-01-21T10:30:20+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/\",\"url\":\"https:\/\/www.mitech-ltd.com.sg\/cn\/case_studies\/heating-element-assembly-machine\/\",\"name\":\"Heating Element Assembly Machine\"}}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.mitech-ltd.com.sg\/cn\/wp-json\/wp\/v2\/case_studies\/394"}],"collection":[{"href":"https:\/\/www.mitech-ltd.com.sg\/cn\/wp-json\/wp\/v2\/case_studies"}],"about":[{"href":"https:\/\/www.mitech-ltd.com.sg\/cn\/wp-json\/wp\/v2\/types\/case_studies"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mitech-ltd.com.sg\/cn\/wp-json\/wp\/v2\/media\/1807"}],"wp:attachment":[{"href":"https:\/\/www.mitech-ltd.com.sg\/cn\/wp-json\/wp\/v2\/media?parent=394"}],"wp:term":[{"taxonomy":"case_study_categories","embeddable":true,"href":"https:\/\/www.mitech-ltd.com.sg\/cn\/wp-json\/wp\/v2\/case_study_categories?post=394"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}